Leveling system maxi set grey, order no 12539

Quantities levelling system 150x
Quantities levelling system 1500x
Leveling system maxi set grey
Price
 
189,00 excl. VAT
224,91 incl. VAT
* including VAT plus shipping
Stock
sold out
not on stock!
This Article is currently not on stock. Please enter your mail and we will notify you when the product is back on stock.
Your request has been accepted
Your mail is incorrect!
The requested article couldnt be found!
An error occured!
Please accept the Privacy Policy
Description

Tile Leveling System Maxi Set, Item No. 12539

 

Attention: For sensitive surfaces we recommend the washers with the article number 12489

 


Perfect grout pattern - without excess teeth or height offset!


Contents:

150 pulling hoods, for 12-20 mm tile thickness (gau)
1500 threaded tabs, for 3 mm joint width (blue)
1 mixing bucket
Easy application:

Step: draw up the adhesive bed as usual, for large format tiles (approx. from format 60 x 60 cm) it is recommended to use the buttering-floating method. Then insert the first tile.
Step: Now insert 1 - 2 basic threaded tabs along the tile edge where the next tile is to be laid, so that one half of the tab base sits under the tile.
Step: Now place the next tile against the first tile so that the threaded tabs are fixed in the joint between the tiles.
Now turn the tension hoods onto the threads of the base tabs. Do not tighten them completely at first; only when all the tension hoods in the immediate vicinity have also been tightened can all the tension hoods be tightened. In this way, the tiles are now all raised or lowered to the same level.
Step: Proceed in this way over the entire area to be laid. As long as the adhesive bed is still wet, the pulling hoods can be tightened at any time, but you should not walk on the tiles while the adhesive is still wet.
Allow the adhesive bed to cure completely. Then the reusable pull hoods can be twisted off and collected, while the threaded tabs remain with the lower part in the adhesive and can be broken off at the predetermined breaking point under the thread and disposed of. The base of the threaded tabs is grouted with and is no longer visible after breaking off.
TILE LEVELING SYSTEM MAXI-SET - WHAT YOU SHOULD BEAR IN MIND:
The prerequisite for the success of a perfect tile floor with the tile laying system is a completely level substrate. As already mentioned, the use of the buttering-floating method is advantageous here, as the risk of hollow layers is significantly reduced and the adhesion between tile and substrate is increased.

Before starting work, test the black as well as the gray tension hoods of the tile laying system on an inconspicuous area of a tile, as these can cause abrasion on very sensitive surfaces. In this case, the company Karl Dahm assumes no liability.
 

Additional Informations
Query on the Item?
Do you have any questions on this item?
Your E-mail Adress
My Question:
Description
Additional Informations
Query on the Item?

Tile Leveling System Maxi Set, Item No. 12539

 

Attention: For sensitive surfaces we recommend the washers with the article number 12489

 


Perfect grout pattern - without excess teeth or height offset!


Contents:

150 pulling hoods, for 12-20 mm tile thickness (gau)
1500 threaded tabs, for 3 mm joint width (blue)
1 mixing bucket
Easy application:

Step: draw up the adhesive bed as usual, for large format tiles (approx. from format 60 x 60 cm) it is recommended to use the buttering-floating method. Then insert the first tile.
Step: Now insert 1 - 2 basic threaded tabs along the tile edge where the next tile is to be laid, so that one half of the tab base sits under the tile.
Step: Now place the next tile against the first tile so that the threaded tabs are fixed in the joint between the tiles.
Now turn the tension hoods onto the threads of the base tabs. Do not tighten them completely at first; only when all the tension hoods in the immediate vicinity have also been tightened can all the tension hoods be tightened. In this way, the tiles are now all raised or lowered to the same level.
Step: Proceed in this way over the entire area to be laid. As long as the adhesive bed is still wet, the pulling hoods can be tightened at any time, but you should not walk on the tiles while the adhesive is still wet.
Allow the adhesive bed to cure completely. Then the reusable pull hoods can be twisted off and collected, while the threaded tabs remain with the lower part in the adhesive and can be broken off at the predetermined breaking point under the thread and disposed of. The base of the threaded tabs is grouted with and is no longer visible after breaking off.
TILE LEVELING SYSTEM MAXI-SET - WHAT YOU SHOULD BEAR IN MIND:
The prerequisite for the success of a perfect tile floor with the tile laying system is a completely level substrate. As already mentioned, the use of the buttering-floating method is advantageous here, as the risk of hollow layers is significantly reduced and the adhesion between tile and substrate is increased.

Before starting work, test the black as well as the gray tension hoods of the tile laying system on an inconspicuous area of a tile, as these can cause abrasion on very sensitive surfaces. In this case, the company Karl Dahm assumes no liability.
 

Do you have any questions on this item?
Your E-mail Adress
My Question:

Customers who bought this product also bought these items:

 
72,90 excl. VAT
86,75 incl. VAT
 
8,95 excl. VAT
10,65 incl. VAT
€ 106,74
79,90 excl. VAT
95,08 incl. VAT
 
4,20 excl. VAT
5,00 incl. VAT